kWh per unit produced
Specific energy, continuously, per machine. A mill outside its setpoint burns money even when the dashboard says it's working.
“Energy is eating my margin — and now they want ESG reports.”
How many kWh each unit produced costs, measured continuously and against a setpoint. It's the number that connects what happens on the floor with the P&L — and the one ESG reporting is starting to ask for.
Specific energy, continuously, per machine. A mill outside its setpoint burns money even when the dashboard says it's working.
At La Plomosa the scientific setpoint turned out to be 14.15 kWh/ton. That number didn't come from a manual: it came from instrumenting the mill and letting it talk.
The model tells real production apart from idling, starting up and waiting. That's where the unproductive time no report was showing turns up.
Coming soon: emitted gases (CO₂e) and variables aligned with the Paris Agreement, so the sustainability report comes out of the same measurement instead of a separate estimate.
A current meter tells you how much energy went in. Specific energy also requires knowing how much was produced in that same time window — which is why this module needs both signals synchronised, and that's precisely what the platform already does.
The install is the usual one: non-invasive sensing, 1 day per machine, without stopping the operation and with a 120 V outlet as the only physical requirement.
They all run on the same data and the same hardware. Turn on one, turn on six — the bill grows per machine, not per module.
20 h/day of unproductive time exposed
A mill instrumented in 1 day that exposed 20 h/day of unproductive time and set its setpoint at 14.15 kWh/ton.
It's the kWh it costs to process each ton or each unit. It's the number that connects the operation with the P&L: a machine outside its setpoint burns money even when it 'is working'. Kinnil computes it continuously and uses AI to classify the equipment's states.
A meter tells you how much energy went in, not how much each unit produced cost. That requires measuring consumption and output synchronised on the same machine — the difference between a data point and an actionable indicator.
Not yet: emitted gases and variables aligned with the Paris Agreement are in development. What is running today is specific energy, which is the base that layer will be computed on.
We install on 1–2 machines, measure your real baseline and present the findings with your own data. Success criteria agreed from day one.